INFORMATION ABOUT PRIORITIES BETWEEN THE
DIFFERENT MODES
PRINCIPE
In Comfort, Eco and Frost protection modes, only orders
of the presence sensor and those of the open window
sensor will be considered.
In Auto mode, the device can receive different orders
coming from :
— 7-day and daily programming integrated (Comfort or
Eco orders);
— 6-order pilot wire if connected to central control unit;
— Open window detector;
— Presence detector.
In general, the command to set the lowest temperature
is executed, except when the pilot wire is connected to
an energy management system, in which case the pilot
wire pilot commands have priority.
— If an open window or an absence of more than 72
hours is detecting, priority is given to switching to
frost protection, unless a shed load is commanded
on the pilot wire.
Special case of self-programming where the temperature
level in the room is decided according to the learning of
the lifestyle and the optimization mode selected (Opti
Comfort or Opti Eco):
— During the programmed passage in period Eco, if
a presence is detected in the room, it will be taken
into account and the appliance automatically switches
to Comfort mode
— During the programmed passage to the Comfort mode
period, the absence detection system is temporarily
suspended (30 minutes).
— The Boost activation will take precedence over others
orders received except when the standby (stop) order
is present on the pilot wire, the device will switch off
and the Boost will be not activated.
60
EXAMPLES
7 day and daily programming = Comfort
+
Pilot wire 6 orders
= Eco
7 day and daily programming = Comfort
+
Pilot wire 6 orders
+
Presence detector
= Frost protection
7 day and daily programming = Eco
+
Pilot wire 6 orders
+
Presence detector
+
Open window detector
= Standby mode
= Eco
3
= Eco
= Frost protection
3
= Stop (standby mode)
= Eco
= Frost protection