⑭ You can set the Boost maximum temperature by
pressing
or
from 25°C to 39°C by intervals
of 1°C.
⑮ To save and move automatically to the next setting,
press
. To exit the user settings, press
SETTING THE TEMPERATURE UNIT
The pre-set temperature unit is degrees Celsius. This
setting cannot be changed on this version.
⑯ To move automatically to the next setting, press
To exit the user settings, press
RESTORING FACTORY SETTINGS
To return to the factory settings, follow these steps:
① From the setting of the temperature unit, press
rest appears on the display.
② N O appears. Press
yes = Factory settings reset
NO = Factory settings not reset
64
twice.
twice.
or
to select YES.
③ Press the key
to its initial configuration and goes back automatically
to the home display of the user settings.
The following parameter values will be restored:
Parameters
Operating
Comfort setting temperature
Boost duration
Keypad lock
Backlighting
Backlighting
.
Eco mode temperature lowering-level
Frost protection temperature
Super Comfort
Minimum set of Comfort setting
temperature
Maximum set of Comfort setting
.
temperature
Maximal Boost duration
Maximum ambient temperature for
the automatic stop of the Boost
Temperature unit
Press
to exit the user settings.
for 5 seconds. The device returns
5 sec.
Factory settings
19°C
60 min.
Disabled
L3
-3,5°C
7°C
Enabled
7°C
30°C
60 min.
35°C
°C