Expert Settings; Access; Ambient Temperature Sensor Adjustement - TERMA WEBL1K906F Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT: THIS OPERATION IS RESERVED FOR PROFESSIONAL INSTALLERS ONLY; ANY WRONG CHANGES WOULD
RESULT IN CONTROL ANOMALIES.

EXPERT SETTINGS

ACCESS

To access the Expert settings in 5 steps, enter the Auto, Comfort, Eco or Frost protection mode, then:
Information display
1
1
Press for 5
seconds
Information displays
Setting sequence:
Ambient temperature sensor adjustement → Setting the energy type → Setting the power → Internal temperature
monitoring → Restoring factory settings
AMBIENT TEMPERATURE SENSOR
ADJUSTEMENT
OVERVIEW
Use this function if the measured temperature (measured
by another reliable thermometer) differs by at least 1°C
or 2°C compared to the set temperature of the radiator.
The calibration adjusts the temperature measured by the
ambient temperature sensor to compensate for a deviation
from + 5°C to - 5°C by intervals of 0.1°C.
2
Press briefly
twice
Pro = Expert settings
4
Long and simultaneous
10 seconds press
Information displays
1
5
Press briefly

AMBIENT TEMPERATURE SENSOR ADJUSTEMENT

① If the room temperature difference is negative.
Example:
Setting temperature (expected) = 24°C.
Ambient temperature (reading on a reliable thermom-
eter) = 22°C.
Difference measured = -2°C.
Important: Before carrying out the calibration it is rec-
ommended to wait for 4h after the setting temperature
modification to insure that the ambient temperature is
stabilized.
3
Press for 10
seconds
69
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Webl1k916f

Table des Matières