To correct, do the following:
Sensor temperature = 24°C
(The measured temperature may be different due to the
location of the thermostat in the room).
Decrease the temperature measured by the ambient
temperature sensor by 2°C by pressing
example the measured temperature by the sensor goes
from 24°C to 22°C.
② If the room temperature difference is positive.
Example :
Setting temperature (expected) = 21°C.
Ambient temperature (reading on a reliable thermom-
eter) = 23°C.
Difference measured = +2 °C.
To correct, do the following:
Sensor temperature= 21°C.
(The measured temperature may be different due to the
location of the thermostat in the room).
Increase the temperature measured by the ambient tem-
perature sensor by 2°C by pressing
the measured temperature by the sensor goes from 21°C
to 23°C.
70
To validate the new value press
settings, press
THE RESET TO ZERO OF THE SENSOR
CALIBRATION
. In our
To put the value of the correction to «0», do the following :
① When the temperature measured by the sensor appears,
press
② To save and move automatically to the next setting
press
3 times.
SETTING THE POWER
To adapt the controller to the radiator and be able to
correctly estimate energy consumption, it is necessary
to set the power of the device.
① Preset value: 500 W. Select a value between 300 W and
1500 W by pressing
the installed heating cartridge on the radiator packaging
or on the sales document.).
. In our example
3 times.
or
for at least 3 seconds.
3 sec.
. To exit the Expert settings, press
Important: These changes should be made by
a qualified installer during the first installation
or
. To exit the Expert
. (Find the power of