USER SETTINGS
ACCESS
To access the User settings in 3 steps, enter the Auto, Comfort, Eco or Frost protection mode, then:
Information display
1
1
Press for 5
seconds
Setting sequence:
Backlighting → Eco mode temperature lowering-level → Frost protection temperature → Super comfort → Comfort
setting temperature limit → Maximal Boost duration → Maximum ambient temperature → Temperature unit.
BACKLIGHT SETTING
① Three modes can be set:
L1 = Temporary backlighting: Backlight of the display
when a button is pressed or during presence
detection.
L2 = Non-stop backlighting: Backlight of the display
all the time.
L3 = Temporary backlighting: Backlight of the display
when a button is pressed.
L3 mode is the default setting.
Press
or
to choose the setting you require.
Information display
2
1
Press briefly
twice
② Press
To exit the user settings, press
SETTING THE ECO MODE
TEMPERATURE LOWERING-LEVEL
The drop in temperature is set at -3.5°C compared to the
set temperature of the Comfort mode. You can adjust the
lowered level from -1°C to -8°C, by intervals of 0.5°C.
Important: whatever the lowering level set, the Eco setting
temperature will never exceed 19°C.
User = réglages utilisateur
to save and move to the next setting.
twice.
3
Press briefly
61
EN