f) Discharging accumulators ("DISCHARGE")
Normally, it is not necessary to discharge lithium accumulators (contrary to NiCd accumulators).
The accumulator can be charged immediately independent of its current status.
If you still want to discharge such an accumulator, you can set the discharge current between
0.1A and 1.0A.
Proceed further as described in chapter 11. b) with the difference, that the accumulator is not
charged but discharged.
The final discharge voltage differs depending on the set accumulator type and already preset
in the charger. In addition to the accumulator type, the display shows the corresponding
voltage.
• LiPo:
3.0V per cell
• LiIon:
2.5V per cell
• LiFe:
2.0V per cell
If a multi-cell accumulator is connected via the balancer connections, you can
switch between the normal display and the display of the cell voltages during
the discharge process with the "INC" button.
70