Fast Charge ("Fast Chg"); Storing Accumulators ("Storage") - VOLTCRAFT B6 Notice D'emploi

Masquer les pouces Voir aussi pour B6:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

d) Fast charge ("FAST CHG")
When charging a Lithium accumulator, the charge current becomes increasingly lower the
fuller the accumulator due to the applied charge procedure for lithium accumulators. Of course,
this also increases the charging time.
A special charging procedure achieves a higher charge current with fast charging. However,
this reduces the capacity, because the charge process is terminated earlier due to the safety
cutoff in the charger.
This means, a LiPo accumulator, for example, cannot be fully charged using the quick charge
function. Only approx. 90% of the capacity achievable with the normal charge process are
available.
Therefore, quick charging only makes sense if the accumulator is supposed to
be available gain as fast as possible.
The procedure of setting the charge current and the voltage/cell count is the same as with the
normal charge process (see chapter 11. b).
e) Storing accumulators ("STORAGE")
This function can be used to set the accumulator to a certain voltage level, which is regarded
as ideal for storage (LiPo = 3.85V, LiIon = 3.75V, LiFe = 3.3V).
Depending on the cell voltage, the accumulator is either charged or discharged. Of course,
with a multi-cell accumulator pack, this only makes sense if a balancer connection is available.
The procedure of setting the current and the voltage/cell count is the same as with the normal
charge process (see chapter 11. b).
The set current is used for charging/discharging.