Ind131 J-Box; Ind331 Harsh Enclosure; Desktop Mounting - Mettler Toledo IND131 Guide D'installation

Masquer les pouces Voir aussi pour IND131:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 236
2.2.5.

IND131 J-Box

The junction box version of the IND131 terminal is designed to mount to a flat surface using four
bolts or screws (not included). The mounting hole dimensions are given in Figure 2-18, in
millimeters and [inches]. Make certain there is enough room below the enclosure for all the cable
entries. Ensure that the mounting hardware is capable of supporting the weight of the terminal,
which is approximately 3.5 kg (8 lb).
2.2.6.

IND331 Harsh Enclosure

The harsh enclosure is made of stainless steel with a front panel angle of approximately 38
degrees. The harsh enclosure is designed to rest on a flat surface such as a table or desk top, or it
can be mounted to a vertical surface with optional mounting brackets.
2.2.6.1.

Desktop Mounting

When the terminal will be placed on a flat surface, the four rubber feet included with the terminal
should be adhered to the bottom of the enclosure to prevent sliding. Locate the four rubber feet,
remove the protective paper from the adhesive, and press the feet onto the corners of the bottom of
the enclosure as shown in Figure 2-19.
64067480
|
11
|
05/2018
Figure 2-18: J-Box Mounting Template
METTLER TOLEDO IND131/IND131x/IND331/IND331xx Installation Manual
2-11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ind131xxInd331Ind331xxInd131 sérieInd331 série

Table des Matières