ventilation
min.
10 mm
min.
865 x 6 mm
150
C
B
The electronics in the appliance require cooling. The
ventilation openings are located on the underside of
the appliance. It must be possible for cool air to be
drawn in through these openings. The appliance is
fitted with outlet openings at the front.
The kitchen unit will require a few modifications to
allow optimum cooling of the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min. 100 cm
Ventilation is via plinth and rear of cupboard.
Attention! Do not allow the ventilation openings on
the underside of the appliance to be blocked by a
drawer.
Where there is a drawer, a gap of at least 865 x 6 mm
should be made at the front.
The distance between drawer A and the hob should
be a minimum of 10 mm.
No extra modifications for ventilation need be made
A
where there is a fixed panel.
Above a oven of the ATAG brand
Recess height minimum 600 mm
Ventilation is via plinth and rear of oven.
Where there is a oven, a gap of at least 6 mm should
be made at the front.
Cut out ventilation openings "A" + "B" (100 cm
Make an opening in the side wall "C" of the kitchen
600
cupboard for leading the connection cable through.
The hob may only be combined with ATAG ovens, not
with combi-microwave ovens. The cut-out section
A
"C" must be made over the full cabinet depth on both
sides if the worktop is thinner than the 48 mm hob.

possibilities for building in

installation
2
).
2
).
GB 29