6. Service

6.1. General

All maintenance activities must happen at an disconnected machine and hoses without pressure.
Checking the electric components can happen exclusively by an expert.
Exclusively accessories and replacement components which have been approved by the manufacturer can be
used. Directly after the activities all securities- and protection parts must be assembled, before the machine is put
into functioning.
"a golden rule" that contributes to a perfectly working machine with few problems, is well the following:
A DAILY CONTROL AND CLEANING OF THE MACHINE FREQUENTLY DO WONDERS!
To be able to guarantee a perfectly working system, one has first necessary a reliable and technical well consid-
ered machine, which is then faced secondly at regular times with a thorough maintenance. Therefore the experi-
ence and the "know-how" of DiBO a technical good working machine is insured and large maintenance turns
can be carried out by experienced DiBO technicians by means of appointment or maintenance contract, we can
suppose in advance that it is satisfied to these two points.

6.2. Maintenance diagram

6.2.1 General
The user can carry out only those actions for which in this book authorisation are given.
Each other act has been prohibited!
For the maintenance turns of burner kettle, high pressure pump, combustion engines and of components
which have to do with the security, one must contact our DiBO technicians.

6.2.2. Periodic maintenance

- Control of the electric cables, high and low pressure hoses
and coupling and control of the oil level.
- Refreshing reduction gearbox oil.
- All following refreshments of pump oil / reduction gearbox oil.
- Extra control/replacement of joints, valves, o- rings by ac-
knowledged DiBO- technicians!

6.2.3. Control/refreshing of oil level and pump oil

Check for each use of the machine the oil with the oil level glass or with the oil level bar.
Oil must stand right with the sign of the oil level glass, if the this case is not, oil tops up until the sign.
If oil looks forward to there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the drain plug below the pump.
- Unbolt the tap with the oil level bar.
- Catch all oil in a barge and remove oil like further described in the guide.
- Force up the drain plug there and top up the oil in the breach to the upper part to on the mark line.
- Force up the tap with the oil level bar there.
- Recommended oil: 1.836.042.
6.2.4. Control
/refreshing the reduction oil
Check for each use the machine the oil with the oil level glass.
Oil must stand right with the sign of the oil level glass, if the this case is not, oil tops up until the sign.
If oil looks forward to there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the drain plug below the reduction gearbox.
- Catch all oil in a barge and remove oil like further described in the guide.
- Force up the drain plug there and top up the oil in the breach to the upper part to on the mark line.
- Recommended oil: 1.836.015.
- Refreshing pump oil.
- Cleaning water filter.
- Maintenance engine.
- oil level
DiBO n.v. 64
After each use.
First 50 hours.
First 50 hours.
Each 50 hours/each month.
Each 400 hours/yearly.
See enclosed motor instruction manual.
Pay attention, shorter maintenance
intervention necessary to the motor!
Each 600 hours.