Fronius Primo 208-240 Instructions De Service page 27

Masquer les pouces Voir aussi pour Primo 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Procedure:
Download the "froxxxxx.upd" update file
1
(e.g., at http://www.fronius-usa.com; xxxxx stands for the respective version
number)
IMPORTANT! To ensure problem-free updates of inverter software, the USB
stick should have no hidden partitions and no encryption (see section "Suitable
USB Sticks).
Save the update file to the highest data level of the USB stick
2
Open the data communication area
3
Insert the USB stick with the update file into the USB socket in the data
4
communication area
In the Setup menu, select the menu item "USB" and then "Update Software"
5
Press the "Enter" key
6
Wait until a comparison of the current software version on the inverter and
7
the new software version is displayed:
-
Page 1: Recerbo software (LCD), key controller software (KEY), country-
setup version (SET)
-
Page 2: Power stage set software
Press the "Enter" key after every page
8
The inverter begins copying the data.
"UPDATE" and the saving progress of the individual tests is displayed in % until
the data for all electronic assemblies is copied.
After the copying is complete the inverter updates the required electronic as-
semblies one after the other.
"UPDATE", the relevant assembly, and the update progress are displayed in %.
The inverter updates the display in the last step.
The display remains dark for approx. 1 minute, the control and status LEDs
flash.
When the software update is complete, the inverter switches to the startup
phase and then to grid power feed operation. The USB stick can be removed..
Individual settings in the Setup menu are retained when the inverter software
is updated.
Logging Interval
Activating / deactivating the logging function, as well as setting the logging in-
terval
Unit
Minutes
Setting range
30 Min. / 20 Min. / 15 Min. / 10 Min. / 5 Min. / No Log
Factory setting
30 Min.
30 Min.
The logging interval is 30 minutes; new logging data are
saved to the USB stick every 30 minutes.
27

Publicité

Table des Matières
loading

Table des Matières