The INFO menu item
INFO
Measured values
Measured val-
LT status
ues
Grid status
LT Status
Grid status
INFO
(information on the device and software)
Display range:
PV Iso.
Insulation resistance of the photovoltaic system
(for ungrounded solar modules and for solar modules with
negative pole grounding)
Ext. Lim.
External power reduction in percent, e.g.: specified by grid
operator
U PV1
Real-time DC voltage at the terminals, even if no energy is
being fed in by the inverter (from first MPP Tracker)
U PV 2
Real-time DC voltage at the terminals, even if no energy is
being fed in by the inverter (from second MPP Tracker)
GVDPR
Mains voltage-dependent power reduction
Fan #1
Percentage value of fan target power
The status indicator of the last error that occurred in the in-
verter can be shown.
IMPORTANT! Status codes 306 (Power low) and 307 (DC
low) appear naturally every morning and evening due to low
solar irradiance. These status codes are not the result of a
fault.
-
After pressing the "Enter" key, the power stage set status
and the last error that occurred are displayed
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the status and error list
The last 5 grid errors that occurred can be displayed:
-
After pressing the "Enter" key, the last 5 grid errors that
occurred are displayed.
-
Use the "Up" and "Down" keys to scroll through the list
-
Press the "Back" key to exit the grid error display.
PV Iso. / Ext. Lim. / U PV1 / U PV2 /
GVDPR / Fan #1
33