Roi Setup Menu; Thermal Analysis Menu; Thermal Analysis Menu (Spot Meter) - Videotec Ulisse Compact Manuel D'instructions

Masquer les pouces Voir aussi pour Ulisse Compact:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 158

8.1.16.5 ROI Setup Menu

Once inside the ROI Configuration Menu it is
possible to change the region of interest (ROI) used
by the AGC algorithm to calculate the contrast and
brightness levels of the image.
Point 1 Left: Sets the left limit of the ROI.
1.
Point 1 Top: Sets the upper limit of the ROI.
2.
Point 2 Right: Sets the right limit of the ROI.
3.
Point 2 Bottom: Sets the lower limit of the ROI.
4.
ROI SETUP
------------------------
1>POINT 1 LEFT
2 POINT 1 TOP
3 POINT 2 RIGHT : +
4 POINT 2 BOTTOM: +
Fig. 82
46
: -
160
: -
128
160
128

8.1.16.6 Thermal Analysis Menu

1.
Spot Meter: Allows access to the point
measurement configuration submenu.
2.
Isotherm: Allows access to the isotherm
management submenu.
THERMAL ANALYSIS
------------------------
1>SPOT METER
2 ISOTHERM
Fig. 83

8.1.16.7 Thermal Analysis Menu (Spot Meter)

Once inside the Point Measurement menu it is
possible to set one of the following parameters:
Mode: Enables the visualization of the taken
1.
temperature from the 4 pixels to the centre of
the image (in degrees Celsius or Fahrenheit). The
OFF option disables the visualization.
Digital: Enables the visualization of the relative
2.
symbol on the display.
3.
Thermometer: Enables the visualization of the
relative symbol on the display.
SPOT METER
------------------------
1>MODE
2 DIGITAL
3 THERMOMETER:
Fig. 84
>
>
:
OFF
:
N
N
MNVCUCT_1511_EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ulisse compact thermal

Table des Matières