Videotec Ulisse Compact Manuel D'instructions page 60

Masquer les pouces Voir aussi pour Ulisse Compact:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 158
Error E2-WIPER BLOCKED.
PROBLEM
The wiper is either jammed or
CAUSE
broken.
SOLUTION
Check that the wiper is free to move.
Error E3-PATROL WITHOUT
PROBLEM
PRESET or error E4-PATROL, 1
PRESET ONLY.
The presets have not been
CAUSE
programmed.
SOLUTION
Program two or more presets and
then update the Patrol configuration
menu (10.2 Saving a Preset, page 49
e 8.1.10.6 Patrol Menu, page 37).
Error E5-IR TEMP. TOO HIGH or
PROBLEM
error E6-IR FAULT.
The infrared illuminator is not
CAUSE
working properly.
SOLUTION
Save the preset using the relative
control (10.2 Saving a Preset, page 
49).
Error E7-PRST. NOT
PROBLEM
CONFIGURED.
Recalling of a non programmed
CAUSE
preset.
SOLUTION
Contact the authorized service
centre.
58
Error E8-TOUR NOT
PROBLEM
CONFIGURED.
Recalling of a non configured Tour.
CAUSE
SOLUTION
Save the Tour using the relative
control (10.6 Recalling a pattern
(Tour), page 50).
Error E9-TEMP. TOO LOW.
PROBLEM
The environment temperature is
CAUSE
too low.
SOLUTION
The movements of the P&T unit
is blocked to prevent mechanical
damage.
Alarm AL6 :WATER LEVEL LOW
PROBLEM
Low wiper liquid level.
CAUSE
SOLUTION
Fill the tank of the pump using the
suitable wiper liquid.
MNVCUCT_1511_EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ulisse compact thermal

Table des Matières