10.7 Recalling the Home position
Using the control device it is possible to recall a
previously saved Home (Scan n.1) position (for further
information refer to the manual of the control device
in use).
10.8 Enabling the wiper (Wiper)
Do not use the wiper when the outside
temperature is below 0°C or in case of ice.
To activate/deactivate this function, refer to the
manual of the control device used or to the relative
chapter (10.13 Special controls, page 52).
If it is left on, the wiper automatically
disables itself.
10.9 Enabling the washer
(Washer)
When a control is provided, the Pan & Tilt is
positioned with the window in front of the nozzle..
The pump and wiper are activated for a set period of
time. At the end of the operation the P&T returns to
its initial position.
To activate/deactivate this function, refer to the
manual of the control device used or to the relative
chapter (10.13 Special controls, page 52).
For models with washer complete with level sensor,
can also display a video message when the level of
the liquid inside the tank is too low (only if using a
high prevalence pump).
MNVCUCT_1511_EN
10.10 Unit Reboot
For further information refer to the relative chapter (
10.13 Special controls, page 52).
10.11 Manual correction of a
preset focusing
Load the preset whose focus needs to be changed
using the Scan command. Change the focus using
the appropriate keys Focus Far/Focus Near without
changing the Pan/Tilt/Zoom position. Save the preset
using the appropriate Preset command.
The manual correction of the Preset works
only if the Daytime/Nigh-time Autofocus
fields are disabled (8.1.10.5 Preset Menu
(Utility Preset), page 37).
10.12 Switching of the secondary
video output
To select the video signal (integrated module or
thermal camera), please refer to controls Video 2
integrated module and Video 2 thermal camera (
10.13 Special controls, page 52).
51