ADVANCE PLANNING

■ D etermine the exact location of the vent hood.
■ P lan the route for venting exhaust to the outdoors.
■ U se the shortest and straightest duct route possible.
For satisfactory performance, duct run should
not exceed 100 ft. equivalent length for any duct
configurations.
■ R efer to "Duct Fittings" chart to compute the
maximum permissible length for duct runs to the
outdoors.
■ W hen applicable, install any makeup (replacement)
air system in accordance with local building
code requirements. Visit GEAppliances.com for
available makeup air solutions.
CAUTION
To reduce risk of fire and to properly
exhaust air, be sure to duct air outside — do not vent
exhaust air into spaces within walls or ceilings or into
attics, crawl spaces or garages.
■ U se metal ductwork only. These hoods must use
8" round duct.
■ I nstall a wall cap with damper or roof cap at the
exterior opening. Order the wall or roof cap and any
transition needed in advance.
Wall Framing for Adequate Support
■ T his vent hood is heavy. Adequate structural
support must be provided in all types of
installations. The hood must be secured to vertical
studs in the wall, or to a horizontal support.
■ T he vent hood should be on site before final framing
and wall finishing. This will help to accurately locate
the duct work and electrical service.
■ I nstallation will be easier if the vent hood is installed
before the cooktop and countertop are installed.
Decorative Duct Covers
This hood is shipped with a decorative duct cover for
ceiling heights of 7'-11" to 9'-5". ZX90010 duct cover
accessory is available to reach 9'-6" to 10'-5" ceiling
heights. The accessory should be ordered with the
hood and be on site before installation begins.
4

Installation Preparation

POWER SUPPLY

IMPORTANT - (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
■ W iring must be 2 wire with ground.
■ I f the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
■ R oute house wiring as close to the installation
location as possible on the back wall or ceiling.
■ C onnect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
CAUTION
Automatically Operated Device –
To reduce the risk of injury disconnect from power supply
before servicing. This unit is equipped with an integral
disconnecting switch located inside the blower housing.
1" = 2.5 cm; 1' = 0.3 m