INSTALLATION—RECIRCULATING
7
SIZE AND CUT DUCT PIECE
■ H old upper air deflector with duct connector against
the ceiling.
■ M easure from the bottom of the air deflector to the
top of the hood as shown. Reduce that dimension
by 1" to facilitate installation. The duct will cover and
overlap the deflector and the hood outlets.
Measure
length
Duct
length
■ C ut the duct piece to size and slip
onto the bottom of the deflector.
■ P lace the assembled deflector
and duct over the exhaust outlet.
■ H old the assembly against the
duct bracket.
■ D rive 4 screws into the bottom of
the deflector and into the bracket.
■ U se duct tape to seal duct to
the deflector and at the exhaust
outlet.
18
Installation Instructions
Deflector
8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
■ R emove
junction box
cover and
knockout on
J-Box cover
the left side.
■ S ecure the
house wiring
to the junction
box with a
strain relief.
House wiring
J-Box cover
■ C onnect white leads to branch circuit white lead.
■ C onnect black leads to branch circuit black lead.
■ C onnect green/yellow leads to branch circuit green
lead or bare ground lead.
■ S ecure all connections with wire nuts on each
electrical connector.
■ P ush wires into junction box and replace cover. Be
sure wires are not pinched.
■ S ecure J-Box cover with original screw.
Knockout
1" = 2.5 cm; 1' = 0.3 m