DUCT FITTINGS

This Hood Must Use an
6" Round Duct.
It Can Transition to a
3-1/4" x 12" Duct.
Use this chart to compute maximum
permissible lengths for duct runs to
outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
100 foot for 6" round duct
75 foot for 3-1/4" x 12" duct
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled. The
flexible metal duct should be straight
and smooth and extended as much
as possible.
DO NOT use flexible plastic ducting.
NOTE: Any home ventilation
system, such as a ventilation hood,
may interrupt the proper flow of
combustion air and exhaust required
by fireplaces, gas furnaces, gas
water heaters and other naturally
vented systems. To minimize the
chance of interruption of such
naturally vented systems, follow the
heating equipment manufacturer's
guidelines and safety standards
such as those published by NFPA
and ASHRAE. When applicable,
install any makeup (replacement)
air system in accordance with
local building code requirements.
Visit Monogram.com for available
makeup air solutions.
1" = 2.5 cm; 1' = 0.3 m
49-80267 Rev. 4

Installation Preparation

Equivalent
Duct Piece
Dimensions
Round, straight
3-1/4" x 12", 3-1/4" x 24"
straight
6" Round
90° elbow
6" Round
45° elbow
3-1⁄4" x 12"
90° elbow
3-1/4" x 12"or
45° elbow
3-1/4" x 12"
90° flat elbow
6" round to
3-1/4" x 12" transition or
3-1/4" x 24" transition
3-1/4" x 12" to 6"
round transition
6" round to 3-1/4" x 12" or
transition 90° elbow
3-1/4" x 12" to 6"
round transition 90° elbow
6" Round wall cap
with damper
3-1/4" x 12" wall cap
with damper
6" Round roof cap
6" Round roof vent
* A ctual length of straight duct plus duct fitting equivalent. Equivalent
length of duct pieces are based on actual tests conducted by
GE Appliances Evaluation Engineering and reflect requirements for
good venting performance with any ventilation hood.
Equivalent
Quantity
Length*
Used
1 ft.
(per foot length)
1 ft.
(per foot length)
15 ft.
8 ft.
11 ft.
6 ft.
24 ft.
1 ft.
8 ft.
16 ft.
17 ft.
30 ft.
30 ft.
26 ft
26 ft
Total Duct Run
Total
Equivalent
Length
5