7.1 Activating the pedestrian opening
Button 1 on 2- or 4-button remote controls cannot be programmed to control pedestrian opening.
See "Programming the remote controls", page 15, for more information.
1
>2s
Press the
button on the control
electronics for 2 seconds.
The
indicator light comes on.
Move away from the control electronics when testing pedestrian opening.
7.2 Deactivating the pedestrian opening
Repeat the "Activate pedestrian opening" procedure using the button for which the pedestrian opening must be deactivated. The indicator
light
comes on then goes out. The pedestrian opening is deactivated on this button.
2
Position the remote control on the control
electronics target.
EN - Replacing the EXAVIA 500 / WISPA 800 / SGS 201SGS 400 / SGS 501 electronic unit - SOMFY
PEDESTRIAN OPENING 7
3
Press button 2 on the remote control.
The "RADIO" and
indicator lights come
on then go out.
Pedestrian opening is activated on this
button.
<0,5s