WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifica-
tions to products at any time when deemed necessary, maintaining the same intended use and functionality.
Technical characteristics SLH400
Type
Pinion
Peak thrust [corresponding to the ability to
develop a force capable of moving the leaf]
Nominal torque [corresponding to the abil-
ity to develop a force capable of maintain-
ing the movement of the leaf]
Nominal torque speed
Idling speed (the control unit allows 6
speeds to be programmed, approx. equal
to: 100, 85, 70, 55, 45, 30%)
Maximum frequency of operating cycles
(nominal torque)
Maximum continuous operating time (nomi-
nal torque)
Operating limits
Durability
SLIGHT power supply
Thrust maximum absorbed power [equiva-
lent to amperes]
Insulation class
Emergency power supply
Flashing light output
Open Gate Indicator Output
BLUEBUS output
STOP input
Step-by-step Input
OPEN input
CLOSE input
Radio connector
Radio AERIAL Input
Programmable functions
Self-Recognition functions
Operating temperature
Use in acid, saline or potentially explosive
atmosphere
Protection class
Dimensions and weight
TECHNICAL CHARACTERISTICS OF THE PRODUCT
Electromechanical gear motor for the automatic movement of sliding gates for residential use,
complete with electronic control unit
Z: 15; Module: 4; Step: 12.6 mm; Primitive diameter: 60mm
12Nm; corresponding to the capacity to move a leaf with a dynamic friction of up to 400N
6Nm; corresponding to the capacity to move a leaf with a dynamic friction of up to 200N
0.18m/s
0.34m/s
35 cycles / day (the control unit allows up to the maximum described in tables 2 and 3)
10 minutes
In general, SLIGHT is suitable for the automation of gates featuring weights of up to 400 kg or
lengths of up to 6m as shown in Tables 1 and 2
Estimated between 20.000 cycles and 180.000 cycles, depending on the conditions reported in
Table 3
230Vac (+10% -15%) 50/60Hz.
330W
1 (a safety grounding system is required)
With PS124 optional accessory
For 2 LUCYB flashing lights (12V, 21 W lamp)
For one 24V maximum 4W bulb (the output voltage may vary between –30 and +50% and can
also control small relays)
One output with a maximum load of 15 BlueBus units
For normally open contacts, for 8,2KΩ; constant resistance, or normally closed contacts; with
selfrecognition (any variation from the memorized status causes the "STOP" command)
For normally open contacts (the closing of the contact causes the "STEP-BY-STEP" command)
For normally open contacts (the closing of the contact causes the "OPEN" command)
For normally open contacts (the closing of the contact causes the "CLOSE" command)
"SM" connector for SMXI and SMXIS receivers
52Ω for RG58 or similar type of cable
8 ON-OFF functions and 8 adjustable functions (see tables 7 and 9)
Automatic identification of devices connected with the BlueBus outlet
Self-recognition of the type of "STOP" device (Normally Open, Normally Closed contact or 8,2KΩ)
Self-recognition of the gate length and calculation of the deceleration points and the partial open-
ing point.
-20°C ÷ 50°C
No
IP 44 on the finished product if installed according to proper installation criteria
131x135xh405; 6.5 kg