Nice Slight Instructions Et Avertissements Pour L'installation Et L'utilisation page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
L6
Open
Partially
L7
Mainte-
nance
warning
L8
List of mal-
functions
Note: "
" represents factory settings
All the parameters can be adjusted as required without any contraindication; only the adjustment of the "motor force" could require special care:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the safety system or damage the leaf.
• If the "Motor force control" is used in support of the system for impact force reduction, the force measurement procedure must be performed after each adjustment, as envisaged by standard EN 12445.
• Wear and weather conditions may affect the movement of the gate, therefore periodic force readjustments may be necessary.
01. Press and hold the "Set" key for about 3 seconds;
02. Release the key when the "L1" LED starts flashing;
03. Press the keys "s" or "t" to move the flashing LED onto the input LED representing the parameter which is to be
changed;
04. Press and hold the "Set" key; the "Set" key must be kept pressed during steps 5 and 6;
05. Wait approx. 3 seconds, after which the LED representing the current level of the parameter which is to be modified will light up;
06. Press the key "s" or "t" to move the LED representing the parameter value;
07. Release the "Set" key;
08. Wait 10 seconds (max.) to leave programming.
Note – Points 3 to 7 can be repeated during the same programming phase in order to set other parameters
Examples of programming: Level 1 and level 2
Level one: the sequence to follow in order to change the factory settings of the functions for activating "Automatic Closing" (L1) and "Always close"
(L3) have been included as examples.
01. Press and hold the "Set" key for about 3 seconds;
02. Release the key when the L1 LED starts flashing;
03. Press the Set key once to change the status of the function associated with L1 (Automatic closing).
LED L1 will now flash with long flashes;
04. Press the t key twice to move to L3;
05. Press the Set key to change the status of function associated with L3 (Always close).
LED L3 will now flash with long flashes;
06. Wait 10 seconds (max.) to leave programming.
Important – Once these operations have been completed, to indicate that the "Automatic Closing" and the "Always Close" functions are active the L1 and
L3 LEDs must remain on.
L1
0.5 mt
L2
1 mt
L3
1.5 mt
L4
2 mt
L5
2.5 mt
L6
3 mt
L7
3.4 mt
L8
4 mt
L1
Automatic (depending on the severity of the manoeuvre)
L2
1000
L3
2000
L4
4000
L5
7000
L6
10000
L7
15000
L8
20000
L1
Result of 1st manoeuvre (most recent)
L2
Result of 2nd manoeuvre
L3
Result of 3rd manoeuvre
L4
Result of 4th manoeuvre
L5
Result of 5th manoeuvre
L6
Result of 6th manoeuvre
L7
Result of 7th manoeuvre
L8
Result of 8th manoeuvre
TABLE 8 - To change the adjustable parameters
Adjusts the measurement of the par-
tial opening. Partial opening can be
controlled with the 2nd radio com-
mand or with "CLOSE", if the "Close"
function is present, this becomes
"Open partially".
Adjusts the number of manoeuvres
after which it signals the mainte-
nance request of the automation
(see paragraph "Maintenance notifi-
cation").
The type of defect that has
occurred in the last 8 manoeuvres
can be established (see paragraph
"10.2 Malfunctions archive").
SET
3 s
SET
L1
or
SET
or
SET
10 s
SET
3 s
SET
L1
SET
L1
L3
SET
L3
10 s
English – 9

Publicité

Table des Matières
loading

Table des Matières