USER'S MANUAL. PROMAX-27
The instrument recovers the configuration of the last work session and shows it
on the screen.
At the bottom of the screen you will see next options:
POWER / MOD. / S.R. /
FREQ [F5]:
4.3
CONNECTING TO DEVICES.
The PROMAX-27 permits the connection to a PC or to a serial printer for data
transfer, by means of the connection cable model CC-PX27.
Do not connect any cable other than that supplied by the manufacturer,
otherwise serious damage may be caused to the equipment.
1) Prior to connecting the equipment to a PC, disconnect both from their
respective power supplies.
2) Connect the end of the connection cable corresponding to the PROMAX-27 to
connector [4] and the other end to the serial port of your computer or printer.
Once the computer or printer has been connected, select on the PROMAX-27 the
LOGGER operation mode. If PRINT function is selected data will be dumped to the
remote unit through the serial port.
The communication parameters used by the PROMAX-27, and which therefore
must be defined on the remote unit (PC ) are the following:
Rate
Data bits
Parity
Stop bits
The remote control software RM-TELECOM (included accessory) permits to carry
out from a computer the following options:
09/2010
Pressing this key you can navigate among editable
parameters. To change them, use the Cursor keys or
the alphanumeric keypad as appropriate. POWER, for
changing the power signal level, the margin of values
are from 60 to 110 dBµV; MOD for changing the type of
modulation of the signal, the possible values are QAM8,
QAM16, QAM32, QAM64 and QPSK.; S.R., for
changing the symbol rate of the pilot signal, the
possible values are: 160, 320, 640, 1280, 2560 and
5120. FREQ, for changing the frequency of a pilot
signal, the margin of possible values are from 5 MHz to
50 MHz.
57600 bauds
8 bits
None
1
Page 59