LEVEL / POWER
AV - C/N / MER
AV-CN / MER-
BER
(*) Note:
The BER measurements represent an increase of the data acquisition time.
To leave the configuration menu of the DATALOGGER mode, just press the key of
the operating mode you wish to access.
4.3
Connection to a Computer or Printer.
The PROMAX-10 permits the connection to a PC or to a serial printer for data
transfer, by means of the connection cable model CC-208 .
Do not connect any cable other than that supplied by the manufacturer,
otherwise serious damage may be caused to the equipment.
1) Prior to connecting the equipment to a PC, disconnect both from their
respective power supplies.
2) Connect the end of the connection cable corresponding to the PROMAX-10
to connection [8] and the other end to the serial port of your computer or
printer.
Once the computer or printer have been connected, select on the PROMAX-10
the LOGGER operation mode. If PRINT function is selected data will be dumped to the
remote unit through the serial port.
The communication parameters used by the PROMAX-10 , and which therefore
must be defined on the remote unit (PC or printer) are the following:
Rate
Data bits
Parity
Stop bits
Page 38
ANALOGUE CHANNELS
Audio /
Level
Video
Ratio
Yes
-
Yes
Yes
Yes
Yes
USER'S MANUAL. PROMAX-10
DIGITAL CHANNELS
Carrier /
Noise
Power
Ratio
-
Yes
Yes
Yes
Yes
Yes
19200 bauds
8 bits
None
1
MER
BER
-
-
Yes
-
(*)
Yes
Yes
IMPORTANT