5.- To exit Configuration Mode and return to the main menu, press again the
MENU key
Modifiable parameters are next:
a)
CHANNEL PLAN
It allows you to select the channel plan among the ten ones stored by default
in the instrument: CCIR, EIA, HRC, IRC, OIRL, UK, AUNAD, ST2L, AUST,
ONO.
b)
EDIT CHANNEL PLAN
With this option you can edit the active channel plan. Through this option you
may get into the option EDIT (for details refer to section 4.2.2.1).
c)
POWER AT CMTS
It defines the minimum level of signal that should receive the CMTS. It
accepts values between 20 and 120 dBµV. It is editable by curso or
alphanumeric keypad.
d)
UNITS
It allows you to select measurement units to be used among dBmV, dBµV
and dBm.
e)
MAC ADDRESS SELECTION
It validates the MAC code (Media Access Control address) which will be used
to identify you computer. This is a direction that identifies the instrument in a
unique way. There are two options: PREDEFINED, that uses the MAC
address defined by default and appears in the field MAC ADDRESS or
MANUAL that allows you to modify the MAC address, defining the address
we want.
f)
MAC ADDRESS
It allows you to enter the MAC code that will be used to identify the
equipment.
g)
THRESHOLD
It defines the minimum level of signal to detect. It is editable by the cursor
keys
threshold is represented in the chart by a dotted line. All measures below the
threshold value will not appear on screen. At the LOGGER function will not be
measured channels below the threshold value. At the SEARCH function will
not be searched channels below the threshold value.
Page 18
[13]
[7] and the alphanumeric keypad. At the SCAN function, the
USER'S MANUAL. PROMAX-27
09/2010