Tableau de sélection et références de commande
Power
Magnetiz-
Efficiency Rated
factor
ing current
η
I
μ
rated
cos ?
A
400 V 3 AC line voltage, Vector Control
0.87
60
0.922
0.86
78
0.930
0.87
100
0.933
0.86
95
0.944
0.85
135
0.948
0.84
170
0.951
0.82
158
0.956
0.81
218
0.958
0.82
252
0.960
0.86
163
0.962
0.87
184
0.963
0.87
234
0.965
4)
Output type
:
Vibration severity
grade:
Coupling
N
Coupling
R
Belt/incr. cantilever forces
N
Belt/incr. cantilever forces
R
Shaft extension (DE):
Balancing:
Fitted key
Half-key
Fitted key
Full-key
Plain shaft
–
Paint finish:
Primed
Anthracite (RAL 7016), standard paint finish
Anthracite (RAL 7016), special paint finish
Special versions:
Specify supplementary order code and plain text if applicable (see Options).
1)
n
: Max. permissible thermal speed at constant output or speed,
2
which is at the voltage limit when P = P
2)
n
: Max. permissible speed that is continuously permitted without
S1
speed duty cycles.
3)
n
: Maximum speed which must not be exceeded.
max
4)
See Table "Permissible combinations of mechanical designs".
Moteurs asynchrones 1PH7 (PM)
Manuel de configuration, (APH7P), 05/2007, 6SN1197-0AC71-0DP0
Moment of
Weight,
frequency
inertia of
approx.
f
J
rated
2
Hz
kgm
/
kg/lb
2
lb
-in-s
f
17
4.2/37.17
1300/2866.5
17
5.2/46.02
1500/3307.5
17
6.3/55.76
1700/3748.5
27
4.2/37.17
1300/2866.5
27
5.2/46.02
1500/3307.5
27
6.3/55.76
1700/3748.5
38.6
4.2/37.17
1300/2866.5
38.6
5.2/46.02
1500/3307.5
38.6
6.3/55.76
1700/3748.5
58.7
4.2/37.17
1300/2866.5
58.7
5.2/46.02
1500/3307.5
58.7
6.3/55.76
1700/3748.5
Shaft and flange accuracy:
N
R
N
R
.
rated
1.3 Tableau de sélection et références de commande
1PH7 asynchronous motor
Order No.
7 7 7
1PH7284- . . B . . - 0
7 7 7
1PH7286- . . B . . - 0
7 7 7
1PH7288- . . B . . - 0
7 7 7
1PH7284- . . C . . - 0
7 7 7
1PH7286- . . C . . - 0
7 7 7
1PH7288- . . C . . - 0
7 7 7
1PH7284- . . D . . - 0
7 7 7
1PH7286- . . D . . - 0
7 7 7
1PH7288- . . D . . - 0
7 7 7
1PH7284- . . F . . - 0
7 7 7
1PH7286- . . F . . - 0
7 7 7
1PH7288- . . F . . - 0
A
B
E
F
A
C
J
5)
The rated output current of the Motor Module is lower than the motor
rated current.
6)
When ordering option L27 , please also select option M84 (insulated
version of encoder).
7)
Speed is limited to lower values in some cases. The following restric-
tion applies: Max. output frequency < 5 × motor rated frequency.
Description du moteur
SINAMICS S120 Motor Module
Rated output current
I
rated
A
Order No.
200
6SL3120-1 T E32-0AA0
200
6SL3120-1 T E32-0AA0
260
6SL3320-1 T E32-6AA0
260
6SL3320-1 T E32-6AA0
310
6SL3320-1 T E33-1AA0
380
6SL3320-1 T E33-8AA0
5)
310
6SL3320-1 T E33-1AA0
490
6SL3320-1 T E35-0AA0
5)
490
6SL3320-1 T E35-0AA0
490
6SL3320-1 T E35-0AA0
490
6SL3320-1 T E35-0AA0
605
6SL3320-1 T E36-1AA0
0
3
6
–Z
33