1.6 Instructions for securing the ends of wire ropes
Hanging the rope and securing the rope: The end of a newly fitted wire rope has
to be configured in such a way that its end is permanently secured and the structure
of the rope cannot work loose.
The end connection of the wire rope has to be regularly examined (fractured
wires – corrosion – cracks in the sleeve – loose clamping screws etc.).
As end connections you are only allowed to use the following:
⇒Aluminium press-fit connections according to DIN 3093
⇒Splice connections according to DIN 3089 (uncovered)
⇒Rope clamps
Rope clamps (e.g. to DIN 15315
or similar to DIN 43148)
⇒ Wire rope clamps according to DIN 1142 are not allowed to be
used as rope end connections in hoisting operations.
The winch should be given a thorough examination by a competent person at least once a
year. Always ensure the maintenance interval is adhered to. Only use original accessories
and spare parts, otherwise safe function is not guaranteed.
The entire installation has to be examined by a competent person before taking into opera-
tion, when necessary, after considerable changes and every 4 years.
2.
Technical Data
2.1 Functional description
The wire rope winches >BETA< for stages and studios are drum winches with spur gear.
The load is held in every position by 2 electromagnetic ventilating disk brakes operating independently of
one another.
The winch is provided with an electric contactor control with push buttons up/down, emergency stop, main
switch, and electric overload protection.
The winch is equipped with integrated gear limit switches (momentary-contact limit switch and emergency
position switch).
2.2 Main dimensions
Krananhängepunkte
crane suspension points
technische Änderungen vorbehalten
Rope connection secured with addi-
tional rope clamp acc. to DIN 1142
A
B
Symmetrical rope clamps (DIN 15315) are permitted acc. to DIN 56925 and
DIN 56921-11, and wedge end clamps to DIN 43148.
The free end of the rope has to be secured against being pulled through.
Connection type C is prohibited for hoists and load suspension equipment.
design changes under reserve
04.01.411
Permitted only in
elevator building
C
Size
A
B
[mm]
[mm]
P 1
215
300
P 2
270
400
P 3
320
510
P 3.5
320
510
P 4
380
660
430
800
P 5
For detailed specification please ask for our di-
mensional sheet.
changements techniques sous réserve
Aluminium press-fit con-
nections to DIN 3093
Splice connections
DIN 3089 (uncovered)
C
D
[mm]
[mm]
13,5
6
18
8
21
10
21
10
26
12
32
15