Electric wire rope winch >BETA II< BGV C1
English
for stages and studios

4.8 Operating Elements:

The operating elements (operating places) have to be installed in such a way
that the entire load distance can be overlooked from the operator's position.
Push buttons have to be located in reasonable position.

4.9 Protective measures:

Connection, protective measures and safety precautions have to be
effected according to local, national and international regulations.
4.10 Before taking into operation, check:
correct polarity, turning direction, placement of order devices
protective conductor system
insulation resistance
overload protection adjustment (if existing)
function
5.

Operation

Before taking into operation please turn on the main switch.
The required direction is to be initiated by pressing the respective push-button Up - Down .
During operation, the operator always has to observe the load, the room below and above the load and the
load carrying device.
For safety instructions see page 21
In case of occurring faults, immediately stop operation and eliminate the fault.
Always pay attention to correct turning direction of the rope drum.
Never coil up the rope incorrectly.
When overload protection is effective, reduce the load.
In case of danger operate the Emergency stop switch.
Electric control with integrated operating
elements
upper
emergency
Up
Down
lower
emergency
The electronic overload protection is adjusted and is effective at 100 to 110 % of the nominal load.
When overload protection is effective, reduce the load.
Electronic overload protection has to be unlocked by means of a key switch after having reduced the load.
After switching the key, so that the electronically overload protection can work again, the operator has to wait
for min. 20 seconds.
The key has to be safely stored by the operator (never let the key in).
The key switch must not permanently be kept in unlocked position.
When leaving the control place, secure the danger area under the load.
After use, turn off the main switch and (if necessary) close the main switch with a lock.
technische Änderungen vorbehalten
overload
Reset overload
main switch
design changes under reserve
04.01.411
Electric control with external operating
elements
main switch
changements techniques sous réserve
emergency-stop
upper emergency
lower emergency
overload
overload
-RESET
up
down
!
emergency-stop
upper emergency
lower emergency
overload
overload
-RESET
up
down
Seite / page 33