3.4 Technical Specifications
HÜRNER WeldControl 2.0 160
Power Specifications
Voltage
Frequency
Total Rated Power
Heating Element
Facing Tool
Hydraulic & Control Unit
Hydraulic Specifications
Operating Pressure max.
Cylinder
Hydraulic Oil
Operating Range
Ambient Temperature Range
Ingress Protection
Memory for Welding Reports
Data Interface Port
Dimensions
Basic Machine Chassis
Facing Tool
Heating Element
Hydraulic & Control Unit
Carrying and Storage Rack
Weights
Basic Machine Chassis
Facing Tool
Heating Element
Hydraulic & Control Unit
Carrying and Storage Rack
Transport Box
All Reducer Inserts
Version January 2018
230 V
50 / 60 Hz
2.45 kW
0.80 kW
1.05 kW
0.60 kW
160 bar
1.95 cm²
HF-E 15
40 through 160 mm
– 20°C à + 60°C (+ 32°F thru + 140°F)
IP 54
10,000 reports
USB v 2.0 (480 mbit/s)
(see also data at the beginning of Sect
600 x 400 x 410 mm
430 x 330 x 80 mm
450 x 350 x 50 mm
480 x 310 x 300 mm
300 x 370 x 400 mm
27 kg
8 kg
4 kg
28 kg
4 kg
27 kg
21 kg
HÜRNER WeldControl 2.0 160 User's Manual
On/Off Switch
Buzzer
USB Port
Mains Power Cord
RFID Transponder
Reader
.
5)
9
EN