Selecting The Display Language; Setting The Clock; Setting The Buzzer Volume - Hürner WeldControl 2.0 160 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
"Manual Input on" means that the manual input of welding param-
eters or computed parameters is possible, "off," that the manual
input is not allowed.
"Check Ambient Temperature on" means that the outside tempera-
ture is measured before welding, "off," that it not; if the tem-
perature is below 0°C (32°F), welding should be performed only
after taking appropriate steps (heating, tent, for instance).
"Welder Code Options – M – " means that by pressing the MENU
key, the user can access a sub-menu that allows determining
when the welder code, if it is enabled at "Recording," has to be
entered:always, i. e. before evey single welding operation, only
before the first welding operation after switching the unit on or
only after the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting the display and report lan-
guage (see Sect. 4.1.3).
"Date/Time – M – " means that by pressing the MENU key, the user
can access a sub-menu for setting the clock (see Sect. 4.1.4).
"Buzzer Volume – M – " means that by pressing the MENU key, the
user can access a sub-menu for setting the volume of the status
buzzer (see Sect. 4.1.5).
"Temperature Unit – M – " means that by pressing the MENU key, the
user can access a sub-menu for selecting centigrade or Fahrenheit
as the unit for the temperature.
"Pressure Unit – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting bars or pounds per square
inch (psi) as the unit for the pressure.
"Length Unit – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting millimeters or inches as the
unit for the length.
"Inventory Number – M – " means that by pressing the MENU key,
the user can access a sub-menu for entering the number under
which the unit is inventorized with the operating company.
"Number of Tags – M – " means that by pressing the MENU key, the
user can access a sub-menu for entering the number of tags that
are printed automatically after welding with the optional label
tag printer if such a printer is connected.
"Standard – M – " means that by pressing the MENU key, the user can
access a sub-menu for selecting the standard (guideline, norma-
tive scheme) applicable to the welding operation.

4.1.3 Selecting the Display Language

When the "Select Language" sub-menu was selected, the screen
changes and the display reproduced in Display 7 appears.
Use the arrow keys ñ and ò to select one of the options, "Deutsch,"
"English," and "Français" and confirmby pressing the START/SET
key.

4.1.4 Setting the Clock

When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 8 appears.
The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.

4.1.5 Setting the Buzzer Volume

When the "Set Volume" sub-menu was selected, the screen changes
and the display reproduced in Display 9 appears. The buzzer can also
Version January 2018
HÜRNER WeldControl 2.0 160 User's Manual
***** LANGUAGE *****
>Deutsch
English
Francais
Display 7
Date/Time
21.06.13
14:28
Display 8
Buzzer Volume
< ------20-------- >
Display 9
EN
13

Publicité

Table des Matières
loading

Table des Matières