you can select a menu option, then access the selected sub-menu by
pressing the MENU key again.
In the Machine Data sub-menu, the type of machine (its designation
and its cylinder section) to which the hydraulic, control, and data log-
ging/report generation unit is connected, has to be defined (see the
arrow symbol in Display 5). This definition is preset ex works and needs
changing only when, exceptionally, the control unit is connected to
a different machine. To change it, select the proper machine type by
pressing the ñ or ò cursor keys and confirm by pressing the START/
SET key.
If the wrong machine is selected in this menu, all pressure
computations that the machine makes when welding in the
WeldControl mode, will be wrong! Changing to another
Important
machine requires consultation with the manufacturer or an
authorized service shop, as a sensor calibration is then also
recommended. This step requires proper authorization
As an addition to the preinstalled machines, user-defined machine
types can be set as needed at the unused menu entries (a designation
for the machine and its cylinder section have to be entered).
The Sensor Parameters sub-menu, used to calibrate the pressure and
the temperature sensors, should be accessed by authorized staff only
and is, therefore, protected by another access code disclosed only to
such personnel as is allowed to manage these settings.
4.1.1 Setting the Default Configuration of the Machine
In the sub-menus of the Configuration Menu, at "Settings," the pa-
rameters related to the welding unit itself and its operation can be
set. At "Recording," the traceability data that have to or need not be
recorded and written into the reports can be enabled or disabled. The
desired sub-menu is selected using the ñ and ò arrow keys. Then to
access that sub-menu, press the MENU key.
In both parts of the configuration menu, use the ñ and ò arrow keys
to select the desired set-up option. Use the ð arrow key to toggle
between "on" and "off" for that set-up option.
If a "M" is shown next to a set-up option, this indicates that a sub-
menu is accessible here by pressing the MENU key.
On both menu levels (Configuration Menu and its respective
sub-menus), press the START/SET key to save the settings to
memory or press the STOP/RESET key to return to the previ-
Important
ous menu level without saving possible changes.
4.1.2 Understanding the "Settings" Sub-menu
"Check Code Expiry on" means that the welder identification code has
to be current and not expired (default period of validity 2 years
from code issuance), or the welding operation cannot be started,
"off," that the validity of the code is not checked at all.
"Memory Control on" means that when the system memory is full of
reports, the unit will be blocked until the reports are printed or
downloaded, "off," that it works but that the oldest report will
be overwritten.
"Automode on" means that in butt-welding operations the Automode
feature for the easy management of the welding process (see
Sect. 4.3.4) can be used, "off," that the feature is not available.
12
EN
HÜRNER WeldControl 2.0 160 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Settings
>Reporting
Sensor Parameter-M-
Machine Data
>HST 160
HST 200
HST 250
HST 315
SETTINGS
***
Check Code Exp. Off
Memory Control
>Automode
Version January 2018
-M-
-M-
-M-
Display 4
1.95
3.16
5.10
5.89
Display 5
***
On
On
Display 6