4.8.17
Object list
Device Management
Class
Sl
Index
Index
Element
ot
abs
rel
MAND
1
0
1
2
3
4
5
6
MAND
1
1
1
2
3
4
5
6
7
8
MAND
1
2
1
2
3
4
5
6
7
8
MAND
1
3
1
2
3
4
5
6
7
8
9
10
Dispositif de mesure de conductivité SIPAN 32
C79000-B5477-C045-02
MPIP sarl - 94, rue Mohamed Tounsi - 16013 - ROUIBA - ALGERIE
Tél./Fax : 021 81 11 22 - GSM : 070 91 75 15 ou 072 900 654 - E-mail : mpip@mpi-dz.com
The following ob ject list contains all parameters realized with this
device. These parameters are also used by the SIMATIC PDM
software.
This object list is consists of several blocks. To each block is assigned
a certain number of objects.
Default
Object
Parameter description
Value
Device Management
HEADER
0x0000
Dir_ID
Directory ID (reserved)
0x0001
Num_Dir_Rev
Directory Revision Number
0x0001
Num_Dir_Obj
Number of Directory Objects (Directo-
ries)
0x000D
Num_Dir_Entries
Total Number of Directory Entries
0x0001
First_Comp_Dir_Entry
Entry number of first Composite List Dir
Entry
0x0003
Num_Comp_Dir_Entry
Number of Composite List Directory En-
tries
COMPOSITE_LIST_DI-
RECTORY_ENTRY
0x0104
Start_PB_Ref
Directory Index for Physical Block
1
Num_PB
Number of Physical Blocks
0x0205
Start_TB_Ref
Directory Index for first Transducer
Block
4
Num_TB
Number of Transducer Blocks
0x0309
Start_FB_Ref
Directory Index for first Function Block
5
Num_FB
Number of Function Blocks
0x016E
Slot_Index_PB
Physical Block: slot 1, index absolute
110
74
Num_PB_Param
Number of parameters
COMPOSITE_LIST_DI-
RECTORY_ENTRY
0x0142
Slot_Index_TB1
Transducer Block 1: slot 1, index abso-
lute 66
44
Num_TB1_Param
Number of parameters
0x0242
Slot_Index_TB2
Transducer Block 2: slot 2, index abso-
lute 66
44
Num_TB2_Param
Number of parameters
0x0342
Slot_Index_TB3
Transducer Block 3: slot 3, index abso-
lute 66
44
Num_TB3_Param
Number of parameters
0x0442
Slot_Index_TB4
Transducer Block 4: slot 4, index abso-
lute 66
44
Num_TB4_Param
Number of parameters
COMPOSITE_LIST_DI-
RECTORY_ENTRY
0x0110
Slot_Index_FB1
Function Block 1: slot 1, index absolute
16
50
Num_FB1_Param
Number of parameters
0x0110
Slot_Index_FB1
Function Block 2: slot 2, index absolute
16
50
Num_FB1_Param
Number of parameters
0x0110
Slot_Index_FB1
Function Block 3: slot 3, index absolute
16
50
Num_FB1_Param
Number of parameters
0x0110
Slot_Index_FB1
Function Block 4: slot 4, index absolute
16
50
Num_FB1_Param
Number of parameters
0x0110
Slot_Index_FB1
Function Block 5: slot 5, index absolute
16
60
Num_FB1_Param
Number of parameters
Mise en service et fonctionnement
Data Type
Num--
Store
read
write
ber
(acc. to
profile)
unsigned16
6
C
x
unsigned16
8
C
x
unsigned16
8
C
x
unsigned16
10
C
x
min.
max.
valid
Reset to
value
value
values
default at
factory Re-
set
4-65