Télécharger Imprimer la page

Siemens SIPAN 32 Instructions De Service page 112

Masquer les pouces Voir aussi pour SIPAN 32:

Publicité

Les langues disponibles

Les langues disponibles

Mise en service et fonctionnement
Function Block AI 1 (Analog Input)
Class
Sl
Index
Index
Element
ot
abs
rel
BLOCK
1
16
0
16
1
16
2
16
3
16
4
16
5
16
6
16
7
16
8
16
9
16
10
16
11
16
12
STD
1
1
STD
2
2
STD
3
3
STD
4
4
STD
5
5
STD
6
6
6
1
6
2
6
3
STD
7
7
7
1
7
2
7
3
7
4
STD
8
8
8
1
8
2
8
3
8
4
MAND
10
10
10
1
10
2
MAND
11
11
11
1
11
2
MAND
12
12
12
1
12
2
12
3
12
4
MAND
13
13
MAND
14
14
MAND
16
16
MAND
17
17
4-66
MPIP sarl - 94, rue Mohamed Tounsi - 16013 - ROUIBA - ALGERIE
Tél./Fax : 021 81 11 22 - GSM : 070 91 75 15 ou 072 900 654 - E-mail : mpip@mpi-dz.com
Default
Object
Parameter Description
Value
Function Block AI 1
(Analog
Input)
BLOCK_OBJECT
Block features
250
Reserved
250 = not used
2
Block Object
Block type (Function)
1
Parent Class
01 = Input
1
Class
01 = Analog Input
0
DD reference
reserved
0
DD revision
reserved
0x4002
Profiles
PA profile number assigned by PNO
PROFIBUS -- PA = 64
0x0300
Profile Revision
3.0
0
Execution Time
NumberOfParameters
0x0141
Address of VIEW 1
index of view 1
1
Number of View Lists
number of views
0
ST_REV
Identification / device / statistic rev. no.
/ Function block: counter, wich incre-
metns at any change of configuration
parameters
definite tag, which can be specified by
the user
0
strategy
0
to be written by a user for alert treat-
ment
0x08
target mode of block = auto
set block mode
0x08
actual mode
0x98
permitted modes: auto, O/S, man
0x08
set mode in normal operation
0x0000
Current_Alarm
current alarm
0x0000
Unacknowledged
not acknowledged
0x0000
Unreported
not reported
0x0000
Disabled
disabled
BATCH
stored informations für batch processes
BATCH_ID
batch identifikation
RUP
OPERATION
PHASE
OUT
output value: measured value in select
output mode, unit is set in output scale
0
Value
output value
0x4F
Status
quality
PV_SCALE
input / measured value scale
EU100
Input / measured vakue scale/ full--
scale value / corresponding unit from
input
EU0
Input / measured vakue scale/ full--
scale value / corresponding unit from
input
OUT_SCALE
output / output scale
EU100
output / output scale / full--scale vakue
EU0
output / output scale / initial value
UNIT
output / output scale / unit: physicali
output unit
Dec_Point
decimal digits of output value
0
LIN_TYPE
linearization type
0x0109
CHANNEL
channel number: number of transducer
block and relative Index
0.0
PV_FTIME
output / output signal / filter time con-
stant: filter time for output value in se-
conds
0
FSAVE_TYPE
output / failure strategy: reaction if sen-
sor fails
Data Type
Num--
Store
read
ber
(acc. to
profile)
ds32
1
C
x
unsigned16
1
N
x
32
x
1
S
x
1
S
x
unsigned8
1
S
x
ds37
1
D
x
ds42
1
D
x
ds67
1
S
x
ds33
1
D
x
float
2
S
x
ds36
1
S
x
unsigned8
1
S
x
unsigned16
1
S
x
float
1
S
x
unsigned8
1
S
x
Dispositif de mesure de conductivité SIPAN 32
C79000-B5477-C045-02
write
min.
max.
valid va-
Reset to
Value
Value
lues
default at
factory Re-
set
x
x
x
x
0x08,
x
0x10,
0x80
x
x
x
x
x
x
x
x
x
0
x
x
0x0109
x
x
0
500
x
x
2
x

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

Sipan 32x