HLT 2550-L2 CANopen
7 Technical Data
Input data
1)
Measuring ranges
Type
Material
Output data
Output signal
Resolution
Non linearity
Hysteresis
Repeatability
Temperature coefficient
Sampling rate
Ambient conditions
Operation temperature range
Storage temperature range
- mark
Vibration resistance acc. to
DIN EN 60068-2-6 at 50 .. 2000 Hz
Schock resistance acc. to
DIN EN 60068-2-27 (11 ms / half sine )
Protection class acc. to DIN EN 60529
Installation position
Protocol data for CANopen
Communication Profile
NMT-Services
Layer Setting Services and Protocol
Encoder Device Profile
Baudrate
Transmission services
- PDO
- Transfer
Node Id/Baudrate
Other data
Supply voltage
Residual ripple of supply voltage
Current consumption without output
Weight
Reverse polarity protection of the supply voltage and excess voltage protection and short
Note:
circuit protection are provided.
FS (Full Scale) = relative to the complete measuring range
1)
Other measuring ranges on request.
2)
with mounted female connector having the corresponding protection class
Edition: 2017-08-08
30 .. 3000 mm in steps of 50 mm
Profile, with magnetic guidance at the top
Measuring body: aluminium
CANopen
0.05 mm
≤ ± 0.01 % FS, ≥ 0.06 mm
≤ ± 0.1 mm
≤ ± 0.005 % FS, ≥ 0.05 mm
≤ ± 0.01 % FS / °C typ.
Depends on length : :
0.5 ms
1.0 ms
2.0 ms
-20 .. +75 °C, optional -40 .. +75 °C
-30 .. +85 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 10 g
≤ 100 g
2)
IP 67
No restrictions
CiA DS 301 V4.2
CiA DSP 302 V4.1
CiA DSP 305 V2.2
CiA DS 406 V3.2
10 kbit/s . 1 Mbit/s acc. to DS305 V2.2
measured value as 32 bit and float
synchronous, asynchronous, cyclical
Adjustable via LSS
24 V DC ± 20 %
≤ 250 mVpp
˂ 100 mA
Depends on length :
30 mm: ̴ 300 g
3000 mm: ̴ 3900 g
HYDAC ELECTRONIC GMBH
(measuring range ≤ 1200 mm)
(measuring range ≤ 2400 mm)
(measuring range ≤ 3000 mm)
Part No.: 669955
13