Technical Data - HYDAC ELECTRONIC HDA 4800 Notice D'utilisation

Masquer les pouces Voir aussi pour HDA 4800:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HDA 4800

7 Technical data

Input data
Measuring ranges
bar
Overload pressure
bar
Burst pressure
bar
Mechanical Connection
Tightening torque, recommended
Parts in contact with fluid
Output data
Output signal, permitted load resistance
Accuracy to DIN 16086,
Max. setting
Accuracy at minimum setting
(B.F.S.L.)
Temperature compensation
Offset
Temperature compensation
Over range
Non-linearity at max. setting
to DIN 16086
hysteresis
Repeatability
Rise time
Long-term drift
Ambient conditions
Compensated temperature range
Operating temperature range
Storage temperature range
1)
Fluid temperature range
- Marked
2)
mark
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500 Hz
Shock resistance according to DIN EN 60068-2-29
Protection class to DIN EN 60529
Other data
Supply voltage
When applied according to UL specifications
Residual ripple supply voltage
Current consumption
4)
Life expectancy
Weight
Note: Reverse polarity protection of the supply voltage, overvoltage, override and and short circuit protection are provided.
FS (Full Scale) = relative to the full measuring range
1) -25°C with FPM seal, -40°C on request
2)
Environmental conditions according to 1.4.2 UL 61010-1; C22.2 no. 61010-1
3)
with mounted female connector having the corresponding protection class
4)
Measuring ranges ≥ 1000 bar: > 1 million switching cycles (0 .. 100% FS)
Edition: 2017-04-26
6
16
40
60
15
32
80
120
100
200
200
300
G1/4 A ISO 1179-2
G1/2 B DIN EN 837
20 Nm (G1/4); 45 Nm (G1/2)
Mech. connection: Stainless steel
Seal: FPM
4 .. 20 mA, 2-Leiter
0 ..10 V, 3-conductor
0 .. 20 mA, 3 conductor (source)
≤ ± 0.125 % FS typ.
≤ ± 0.25 % FS max.
≤ ± 0.06 % FS typ.
≤ ± 0.125 % FS max.
≤ ± 0.005 % FS / °C typ.
≤ ± 0.01 % FS / °C max.
≤ ± 0.005 % FS / °C typ.
≤ ± 0.01 % FS / °C max.
≤ ± 0.15 % FS max.
≤ ± 0.1 % FS max.
≤ ± 0.05 % FS
≤ 1 ms
≤ ± 0.1 % FS typ. / Jah r
-25 .. +85°C
1)
-40 .. +85 °C / -25 .. +85°C
-40 .. +100 °C
-40 .. +100 °C / -25 .. +100 °C
EN 61000-6-1 / 2 / 3 /4
Certificate No.: E318391
≤ 20 g
≤ 100 g / 6 ms
3)
IP 65 - Binder 714 M18
IP67
10 .. 30 V DC 2 conductor
12 .. 30 V DC 3 conductor
– limited energy – according to 9.3 UL 61010; Class 2;
UL 1310/1585; LPS UL 60950
≤ 5 %
≤ 15 mA
> 10 million cycles, 0 .. 100% FS
approx. 180 g
B.F.S.L.= Best Fit Straight Line
HYDAC ELECTRONIC GMBH
100
250
400
600
200
500
800
1000
500
1000
2000
2000
R
= (U
– 10 V) / 20 mA [kΩ]
Lmax
B
R
= 2 kΩ
Lmin
R
= (U
– 4 V) / 20 mA [kΩ]
Lmax
B
- connection M12x1
- connection EN 175301 - 803
7
1000
1600
2000
1600
2400
3000
3000
3000
4000
E
Part No.: 669868

Publicité

Table des Matières
loading

Table des Matières