16
7 Technical specifications
Input data
Measuring ranges
Type
Material
Seal
Output data
E
Output signal, permitted load resistance
Resolution
Non linearity
Hysteresis
Repeatability
Temperature coefficient
Sampling rate
Ambient conditions
Operation temperature range
Storage temperature range
Fluid temperature range
- mark
Vibration resistance acc. to
DIN EN 60068-2-6
Shock resistance acc. to
DIN EN 60068-2-27 (11 ms)
Protection class acc. to DIN EN 60529
Installation position
Safety-related data
Performance Level
Based on
PL
Architecture
Safety Integrity Level
Based on
SIL
Other data
Supply voltage
Residual ripple of supply voltage
Current consumption without output
Weight
Note:
Reverse polarity protection of the supply voltage and excess voltage protection and short
circuit protection are provided.
FS (Full Scale) = relative to the full measuring range
1)
further variants on request
2)
with mounted female connector having the corresponding protection class
Status: 2017-08-29
at 5 .. 8.2 Hz
at 8.2 .. 150 Hz
HYDAC ELECTRONIC GMBH
HLT 1100-R2- xxx-C01-xxxx-S2PD-000
200 .. 2500 mm
Rod Ø 10 mm for cylinder full integration
Operating pressure range: ≤ 450 bar
Peak pressure acc. to DIN EN ISO 19879: 630 bar
Rod: stainless steel 1.4571
Housing: stainless steel 1.4301
O-Ring: NBR
Backup ring: PTFE
4 .. 20 mA,
Bürde: 200 .. 500 Ω
12 Bit, min. 0.1 mm
≤ ± 0.05 % FS
≤ ± 0.1 % FS
≤ ± 0.1 % FS
≤ ± 0.01 % FS / °C
≤ 30 ms (10 .. 90 %)
-40 .. +85 °C
-40 .. +100 °C
-40 .. +120 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 7.5 mm
≤ 2.0 g
≤ 20 g
IP 67 (cable outlet)
2)
IP 6K9K
(shouldered flange connector M12x1)
No restrictions
DIN EN ISO 13849-1;2008
d
Category 2
DIN EN 61508:2002
2
9 .. 36 V DC
≤ 250 mV
PP
< 100 mA
Depends on length:
100 mm (mit 1 m cable ): ̴ 310 g
2500 mm (mit 1 m cable ): ̴ 1030 g
1)
Part No.: 669938