Operational area
Ambient temperature range (T
Storage temperature
Relative humidity
Installation elevation
Degree of pollution
Noise emission (typically)
Impermissible ambient gases
Equipment and design
Degree of protection
Overvoltage category
DC connection
AC connection
Connection conductor cross-section
Opposing connector
Dimensions (X x Y x Z)
Weight
Display
Communication interfaces
Feed-in management as per
EEG 2012
Integrated DC circuit breaker
Cooling principle
Test certificate
747.431
StecaGrid 3000
indoor rooms, with or without air conditioning
)
amb
26 dBA
coolcept: IP21 (casing: IP51; display: IP21)
coolcept: Multi-Contact MC4 (1 pair)
coolcept-x: Phoenix Contact SUNCLIX (1 pair)
Type
cable diameter 10 ... 14 mm
3 x RJ45 socket (2 x RS485 for connection to Steca-
Grid Vision, Meteocontrol WEB'log or Solar-Log;
EinsMan-ready, via RS485 interface
temperature-controlled fan, variable speed, internal (dust
StecaGrid 3600/-x
–15 °C ... +60 °C
–30 °C ... +80 °C
0 % ... 95 %, non-condensing
≤ 2000 m above sea level
PD3
29 dBA
ammonia, solvents
coolcept-x: IP65
III (AC), II (DC)
Wieland RST25i3 plug
2
, conductor cross-section ≤
4 mm
2
included in delivery
coolcept: 340 x 608 x 222 mm
coolcept-x: 399 x 657 x 227 mm
coolcept: 9 kg; coolcept-x: 11.5 kg
graphical display, 128 x 64 pixels
1 x Ethernet)
yes, compliant with VDE 0100-712
protected)
GB
StecaGrid 4200/-x
31 dBA
131