Switch-on power
Switch-off power
Standby power
Safety
Protection class
Isolation principle
Grid monitoring
Insulation monitoring
Residual current monitoring
Overvoltage protection version
Reverse polarity protection
Application conditions
Operational area
Ambient temperature range (T
Storage temperature
Relative humidity
Installation elevation
Degree of pollution
Noise emission (typically)
Impermissible ambient gases
Equipment and design
Degree of protection
Overvoltage category
DC connection
AC connection
Connection conductor cross-section
Opposing connector
747.431
StecaGrid 1800/-x
no galvanic isolation, transformerless
indoor rooms, with or without air conditioning
)
amb
23 dBA
coolcept: IP21 (casing: IP51; display: IP21)
coolcept: Multi-Contact MC4 (1 pair)
coolcept-x: Phoenix Contact SUNCLIX (1 pair)
Type
cable diameter 10 ... 14 mm
StecaGrid 2300/-x
10 W
5 W
6 W
II
yes, integrated
yes, integrated
yes, integrated
varistors
yes
–15 °C ... +60 °C
–30 °C ... +80 °C
0 % ... 95 %, non-condensing
≤ 2000 m above sea level
PD3
25 dBA
ammonia, solvents
coolcept-x: IP65
III (AC), II (DC)
Wieland RST25i3 plug
2
, conductor cross-section ≤
2
4 mm
included in delivery
StecaGrid 3010/-x
1)
29 dBA
GB
127