Display behaviour
New event messages are displayed immediately. The messages disappear after they have been con-
firmed or their causes have been corrected.
When an event message is confirmed, the user thereby simply confirms that he/she has seen
the message. This does not correct the error that caused the event message to be shown!
If messages exist whose cause has been corrected but have not been confirmed then * is shown in
the status display. If an already confirmed error recurs then it is displayed again.
Operation
Confirming event messages
✔
An event message with the comment
'ESC' /r/s. The event message is confirmed.
Press
u
Displaying event messages
'Event log' in the main menu.
1.
Select
'SET' . The event messages are displayed in chronological order (latest message
2.
Press
first).
3.
Press rs to page through the event messages.
Event messages
Event message
Description
The grid frequency at the inverter is less than the minimum permissible
Grid frequency
value. Due to legal requirements, the inverter switches automatically off
too low
while the error state is present.
u Contact your installer if this error occurs frequently.
The grid frequency at the inverter is greater than the maximum permis-
Grid frequency
sible value. Due to legal requirements, the inverter switches automati-
too high
cally off while the error state is present.
u Contact your installer if this error occurs frequently.