Assembly; Safety Instructions; Before Installation - Burkert 2036 Manuel D'utilisation

Masquer les pouces Voir aussi pour 2036:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.

asseMBly

8.1.
safety instructions
Danger!
risk of injury from high pressure in the equipment/device.
▶ Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
Warning!
risk of injury from improper assembly.
▶ Installation must only be carried out by authorized technicians
and with the appropriate tools.
risk of injury from unintentional activation of the system and
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
8.2.
Before installation
Before connecting the valve, ensure the pipelines are flush.
Pay attention to the flow direction.
Type 2036
Assembly
8.2.1. installation position
• The piston-controlled diaphragm valve can be installed in any
position, preferably with connection B downwards.
• Installation for self-drainage of the body:
see chapter "5.4. Valve self-draining"
8.2.2. preparatory work
Clean pipelines (sealing material, swarf, etc.).
Support and align pipelines.
devices with welded body
note!
damage to diaphragm or actuator.
▶ Before welding in the body disassemble the actuator and
diaphragm.
Remove the actuator from the valve body:
Move the actuator to the upper actuator position (CFA, NC: by
applying pilot pressure; CFB, NO: by removing the pilot pressure).
Mark the position of the actuator in relation to the valve body.
Unscrew the four body screws that connect the valve body with
the actuator. Remove the actuator and the diaphragm.