4.2.3.4 HOW TO PROGRAM THE SELF IGNITION FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
S2 DIP switches combination in which the self ignition function (AI) is listed for the keys you wish
to program.
2.2 Addressing:
f for self-ignition function don't set S1 DIP switches
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (See
f Restore the user code setting on S1.

4.2.3.5 HOW TO PROGRAM THE DOCTOR FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to
switches combination in which the Doctor function (D) is listed for the keys you wish to program.
2.2 Addressing:
f for Doctor function don't set S1 DIP switches
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (See
f Restore the user code setting on S1.
"4.2.1 Preset functions table" on page 20
"4.2.1 Preset functions table" on page
"4.2.1 Preset functions table" on page 20
"4.2.1 Preset functions table" on page
and select a
Example: 0110
20).
and select a S2 DIP
Example: 0110
20).
23