Quick Programming; Special Key Programming; How To Program The Actuator Function - Comelit HFX-7004M Manuel Technique

Masquer les pouces Voir aussi pour HFX-7004M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2.2 Quick programming

For the quick programming of the following functions:
• generic actuator (ACT)
• internal intercom calls (INT)
• internal paging calls (PAG)
• Self ignition main external unit (AI)
• Doctor function (D)
1
f Set the S2 DIP-switches combination corresponding to
the functions that you want to programme for ALL KEYS
as shown in the
20

4.2.3 Special key programming

If the preset functions do not reflect requirements, EACH KEY can be programmed differently by carrying out the steps below.
Special key programming allow to programm the following functions:
• generic actuator and coded actuator (ACT)
• internal intercom calls and general intercom calls to another user code (INT)
• internal paging calls and general paging to another user code (PAG)
• Self ignition main external unit (AI)
• Doctor function (D)

4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
S2 DIP switches combination in which the actuator function (ACT) is listed for the keys you wish
to program.
2.2 Addressing:
f for generc actuator set S1 DIP switches to the combination 11111111
f for coded actuator set S1 DIP switches with the desired address in accordance with
"TAB. A" on page 26.
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (See
f Restore the user code setting on S1
"4.2.1 Preset functions table" on page
"4.2.1 Preset functions table" on page 20
"4.2.1 Preset functions table" on page
Example
Choose S2 DIP-switches combination:
DIP 1
DIP 2
DIP 3
0
1
0
for set all the following function:
PAG /
and select a
20).
DIP 4
0
INT
AI
Example: 1010
21

Publicité

Table des Matières
loading