4.2.3.4 HOW TO PROGRAM THE SELF IGNITION FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
switches combination in which the self ignition function (AI) is listed for the keys you wish to
program.
2.2 Addressing:
„ for self-ignition function don't set S1 DIP switches
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000
„ Restore the user code setting on S1.

4.2.3.5 HOW TO PROGRAM THE DOCTOR MODE

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
switches combination in which the doctor mode (D) is listed for the keys you wish to program.
2.2 Addressing:
„ for doctor mode don't set S1 DIP switches
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000
„ Restore the user code setting on S1.
"4.2.1 Preset function"
table and select a S2 DIP
("4.2.1 Preset function"
table) .
"4.2.1 Preset function"
table and select a S2 DIP
("4.2.1 Preset function"
table) .
Example: 1110
Example: 1000