4.8.2.3 FUNCTION 2: ACTUATOR WITH CODE MODE
√ NOTE: Before programming the module, see "4.9.2.4 COMPATIBILITY TABLE"
By pressing the button programmed as "coded actuator", it is possible to toggle between the different cameras.
Microswitch "S1" must be set as shown in following table:
DIP 1
DIP 2
DIP 3
1
0
0
1
0
1
1
0
0
1
0
1
1
0
0
1
0
1
1
0
0
1
0
1
Example of Address setting
on art. 1409 for control using actuator
code 224
In this mode, with the video entry phone monitor switched on, by repeatedly pressing the actuator with code pushbutton, it is
possible to cycle through ONLY the cameras connected to module 1409 with the corresponding address.
In the same system, it is possible to install up to 8 1409 modules with different codes.
4.8.2.4 COMPATIBILITY TABLE
Compatibility with 1256
Compatibility with 1409
CORRESPONDENCE OF 1409 ADDRESS ACTUATOR WITH CODE ON BRACKET
DIP 4
DIP 5
DIP 6
0
0
0
0
0
0
1
0
0
1
0
0
0
1
0
0
1
0
1
1
0
1
1
0
DIP 1
DIP 2
1
0
Generic actuator mode
No 1256 in "Generic actuator mode"
No other 1409
Address 1409
0
1
2
3
4
5
6
7
DIP 3
DIP 4
DIP 5
0
0
1
COMPATIBILITY OF 1409 WITH 1256 OR OTHER 1409
No 1256 in "Actuator with code mode" with
codes between 220 and 227
Only 1409 in "Actuator with code mode" with
different codes
Actuator on bracket code
220
221
222
223
224
225
226
227
DIP 6
0
Actuator with code mode
29