4.2.3.2 HOW TO PROGRAM THE INTERCOM FUNCTION
Example:
key = general intercom to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to
DIP switches combination in which the intercom function (INT) is listed for the keys you wish to
program.
2.2 Addressing:
f for internal intercom set S1 DIP switches with the same user code of the internal unit.
f for general intercom to another user code set S1 DIP switches with the desired address
in accordance with
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (See
f Restore the user code setting on S1.
4.2.3.3 HOW TO PROGRAM THE PAGING FUNCTION
Example:
key = general paging to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to
DIP switches combination in which the paging function (PAG) is listed for the keys you wish to
program.
2.2 Addressing:
f for internal paging set S1 DIP switches with the same user code of the internal unit.
f for general paging to another user code set S1 DIP switches with the desired address in
accordance with
3
Select the key to be associated with the function
f Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
f Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch setting,
the keys control the programmed functions; the NON-programmed keys control functions
referred to on line 0000 (See
f Restore the user code setting on S1.
22
"4.2.1 Preset functions table" on page 20
"TAB. A" on page 26.
"4.2.1 Preset functions table" on page
"4.2.1 Preset functions table" on page 20
"TAB. A" on page 26.
"4.2.1 Preset functions table" on page
and select a S2
Example: 0100
20).
and select a S2
Example: 0100
20).