4.7 ACTUATOR RELAY MODULE ART. 1256

Intelligent device for controlling a 24 AC/DC 10A relay (fitted) for general uses. Fit a max. of 10 actuator relay modules Art. 1256 on the whole system.
1.
JP3
2
1
JP2
1
JP1
JP1
JP1

4.7.2 Functions

Art. 1256 offers the following functions, depending on the position of jumper JP1:
JP1
• External unit lighting control
• Activation function on Actuator pushbutton.
• Activation function on Actuator with code pushbutton
JP1
External unit lighting control
The relay is operated by closing the C.NO. contact in response to a call from an external unit to any address, on internal
ignition from a video entry phone (e.g. to automatically activate lights, CCTV alarm contacts, etc.). The relay closure time
JP1
can be programmed using a S1 DIP-switch, see "TABLE B"
JP1
Activation function on Actuator pushbutton
The relay is operated by closing the C.NO. contact in response to a Generic actuator call from a video entry phone. The
relay closure time can be programmed using a S1 DIP-switch, see "TABLE B". All art. 1256 modules set for use with this
function are activated simultaneously when the pushbutton on the internal unit is pressed.
JP1
JP1
Activation function on Actuator with code pushbutton
The relay is operated by closing the C.NO. contact if the pushbutton pressed on the video entry phone has been
programmed to send the actuator call with the code of the actuator. The closure time of the relay is fixed at 2 sec. To set
the user code by means of a S1 DIP-switch, see
DIP switches ON
RELAY CLOSURE TIME
The relay for art. 1256 operates in BISTABLE mode, changing its status at every command; if the power supply is cut off, it returns
to the C.NO. position and remains there, even after the power is restored. Bistable mode is available for products with a revision index
equal to or greater than 003.
JP3
2
1
2.
JP3
2
1
2
JP2
1
3.
4.
2
JP2
1
5.
JP1
6.
JP1
JP1
JP1
JP1
JP1
TABLE B: PROGRAMMING RELAY CLOSURE TIME
For external unit light function/stair light function, activation function on actuator pushbutton.
1
ALL
1''

4.7.1 Parts description

1. JP4
2. JP3
3. JP2
To use the actuator relay module with kit HFX-7004M
f Move jumper JP2 to position 2
f Move jumper JP3 to position 2
f Move jumper JP4 to position 2
4. S1 DIP switch for different setting
5. JP1 for functions setting
6. Terminal block for system connection:
NC
relay N.C. contact
COM
relay COM contact
NO
relay NO contact
L L
BUS line input
~+, ~-
power supply input terminals
JP1
JP1
"TABLE A" on page 26.
JP1
2
3
4
2''
4''
8''
JP3
2
1
2
JP2
1
5
6
7
16''
32''
1' 5''
JP1
JP1
JP1
8
2' 10''
27