17. Information on the Charger
Various information is indicated on the display during a charge/discharge process by repeatedly press-
ing the button "DEC".
By repeatedly pressing the "INC" button, you can switch to the display of the individual cell voltage, e.g.
with lithium batteries (this is only sensible if the balancer connections are used with lithium batteries).
70
The balancer cable was connected incorrectly or does not match the
pin assignment of the charger.
The charger has identified an internal problem. Should this message
be displayed permanently, it is possible that the charger is faulty; have
it checked by a specialist workshop or qualified technician.
Voltage of the battery at the end of charging/discharging
Battery capacity for safety cut-off
Time for safety timer
Temperature cut-off on/off; selected cut-off temperature (only with
external temperature sensor, not part of the delivery)
Temperature measured by the external temperature sensor (not part
of the delivery) or the internal temperature sensor.
Current input voltage