7.11
TOOL DRAWER (STP)
It could be necessary to remove the tool drawer.
To do this, extract it completely, then lift it up a
little and pull it out at the same time. In this way
7.12
PLATE CLEANING AND MAINTENANCE
Radiating plates in special steel need regular
maintenance, in particular they need cleaning af-
ter every use that brings moisture or dust on the
plate itself. With cold thermal cooker you have to
remove all the pots and boilers that could maintain
moisture on the plate. Together with the thermal
cooker are given some exclusive products, stud-
ied for the cleaning and the maintenance of the
plate: the abrasive sponge, the cleaning oil and the
plate care oil, on how to use them please read the
instructions written on the bottles. The plates are
all worked in with non acid anti-corrosion oil. The
use of the thermal cooker deletes this oil layer and
so the contact with water may cause small rusty
stains. In this case you have to wipe the plate with
a rag soaked with non acid oil. If the rusty stain
is not being cleaned, you could have to wipe the
plate with a lightly abrasive paper or with the abra-
sive sponge given together with the thermal cook-
7.13
BOILER MAINTENANCE
The boiler tank must be filled up regularly, accord-
ing to the use of the thermal cooker. The decrease
of the water under the minimum level will cause
the lighting of a specific warning light on the con-
trol unit, see chapter 3.7, 3.8 and 3.9.
The sacrificial anode must be controlled at least
once a year, see chapter 3.14.
7.14
MAINTENANCE OF THE LIGHT
WARNING! Before starting any maintenance operation for the light, you must disconnect
it from AC power and be sure that the thermal cooker is not powered. Verify also if the
thermal cooker is cold and if the light was turned on in the previous minutes.
Oven lamp suffers high temperatures. Even if it
is designed to work in these conditions, it could
become out of order. You have to replace it with
a lamp with the same features (halogen lamp 25W
230V 300° connection G9). To replace the lamp
you have to unscrew the lamp cover, remove the
you access to the lower part of the thermal cooker.
To reinsert the wood box you can make the same
process reversed.
er. To restore the protecting layer wipe the plate
with little oil. Do not clean the plate with water. It
is important to be sure that the expansion cuts and
the hole between the plate and the frame are not
obstructed by dust or by other residuals: the plate
could suffer deformations, also permanent. When
it is necessary, you should clean also the beating of
the circled removing eventual residuals. Radiating
steel plates, exposed to continuous heating, trend
slowly to take a burnished colour; if you want to
accelerate the process, repeat frequently the oil
wiping. If the thermal cooker is not used for long
periods, it is suggested to treat the plate with the
plate care oil, in this way the plate is well protected
from moisture. To remove the plate, you have to
lift it up. When you reinsert the plate, keep in mind
to leave the 1 or 2 millimetres to allow the thermal
expansion of the plate itself.
After an extended use of the device, it could be
necessary to make the maintenance of the serpen-
tines when showing calcareous deposits on their
surfaces. In this case it is suggested to empty the
system, removing the serpentines and to proceed
to the mechanical cleaning of them.
lamp, insert the new lamp and finally screw in the
lamp cover. Seldom, it is necessary to clean the
glass of the lamp cover. To make this, you have to
unscrew the lamp cover, remove the external re-
siduals due to the cooking steams, wash the lamp
cover and once it is dry you can screw it in its place.
143