2.6
CONJUNCTION
The conjunction of the thermal cooker to the flue
must be as short as possible and must not have
horizontal or not much inclined parts. The counter-
slope parts are forbidden and must be absolutely
avoided. Near the conjunction, inflammable mate-
rials must not be present. The conjunction must
2.7
FLUE OUTLET PREDISPOSITION
STP is endowed with the predisposition for the
flue outlet on the top and in the rear. The thermal
cookers is given with both the flue outlets cov-
ered. Before connecting the thermal cooker, check
Picture 5 – Predisposition of the flue outlet (STP).
2.8
CCORRECT CONJUNCTION TO THE CHIMNEY
If the conduct of the chimney starts from a low-
er floor than the connection point of the thermal
cooker, it may be necessary to close the conduct
under the connection pipe with fireproof materi-
als. If you have the chimney behind or up, you have
to use the connector with bayonet coupling. This
not go inside the flue. To increase the safety of the
conjunction, we suggest to install a washer on the
wall being sure that the connection between the
washer and the chimney is walled and well sealed.
Also the connection between the thermal cooker
and the conjunction must be fixed and sealed.
that the flue outlet not used is plugged, otherwise
use the accessories given together with the cooker
for this purpose. STP SF model has the flue outlet
only on the top in a fixed position.
must be inserted and turned so that it can remain
blocked. This connector has a tolerance of about 1
cm to make the installation easier. The tolerance
is available according to a single direction which
depends on the orientation of the connector (see
picture 6).