Connection of the power supply cable
Warning
If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
* Unhook the terminal board cover by inserting a screwdriver into the two
hooks "A" (fig. 2.1).
* Unscrew the screw "D" and open completely the cable clamp "E"
(figs. 2.2 - 2.3 - 2.4).
* Position the U bolts "F" onto terminal board "G" (figs. 2.2 - 2.3 - 2.4)
according to the diagrams in fig. 2.5.
* Connect the phase, neutral and earth wires to terminal board "G"
according to the diagrams in fig. 2.5.
* Strain the feeder cable and block it with cable clamp "E" (by screwing
screw "D").
* Close the terminal block cover (check the two hooks "A" are correctly
hooked).
Important
To connect the power supply cable DO NOT unscrew the screws
fixing the cover plate behind the terminal block.
Note
The earth conductor must be left about 3 cm longer than the others.
211