Installation, Operating and Maintenance Instruction
9.2 Model MPA, MPAI (axial intake lines)
See "Appendix" in Operating Instructions for sectional
drawing.
All parts must be cleaned, free of grease and prepared
in accordance with Point 9.1.
Clamp the shaft in a vertical position (24) (use soft
protective wedges), with coupling stub pointing
upwards.
Other assembly work depends on the type of shaft
seal, see Points 4.1 to 4.3, Section Assembly.
Attention: In contrast to the description in Points
4.1 to 4.3, the casing of the shaft seal is exposed.
Proceed carefully in order to avoid damage to the
mechanical seal (GLRD).
Preheat bearing (K1) (max. 80° C) and slide onto
the shaft (24).
Variants: MP, MPA, MPAI 40 and 65 ........roller
bearing (K1) – double row angular ball
bearings (single bearings)
MP, MPA, MPAI 100 and 125 ....roller
bearing (K1) – paired angular ball
bearings in X arrangement
Paired angular ball bearings in X arrangement
Tighten shaft nut (50) while the bearing is still hot.
Fill approx. 60% of the space in the roller bearing
(K1) with grease (when the bearing has cooled
down)
Mount bearing flange (10), at the same time insert
shaft seal casing (18 and 19).
Screw bearing cap (12) to bearing flange (10).
Grease the counter contact surface of the splash
ring packing on the bearing cap (12).
Bring the splash ring (73) into position (groove in
the spacer sleeve) (72).
Lay pressure casing (4) horizontally so that the
shaft can be inserted (24) (mounting plate with
borehole or assembling trestle)
Place pre-mounted unit on the pressure casing (4)
and tighten nuts (M2) (see Supplementary Sheet
for torque)
Rotate shaft (24) to see that it runs smoothly.
The pump must be turned around for further
assembly work (free shaft pointing upwards
vertically)
Assembly as for dismantling.
Lubricate shaft (24)
Check position of the impeller: Insert diffuser
(2/E), slide impeller (1) until impact.
The impeller is in the correct position when the
impeller outlet channel lies within the diffuser
intake channel
(avoids impact losses). Corrections can be carried
out by adding compensation disks or by turning off
MP 100-english
Article No 771074011
the impeller hub on the rear side. This check must
be carried out at every stage.
If a pump is assembled with new impellers, care
must be taken that the first and last stage is
always provided with an impeller with the full blade
diameter. If only one impeller is available with the
full blade diameter it must be used as the first
stage.
Please note that assembly work always starts
with the final stage.
Remove impeller and diffuser once more, insert
O-ring (OR2), re-insert diffuser (2/E).
Insert feather key (PF1 or PF2) for the impeller
that is to be mounted.
Mount impeller (1) (as the O-ring (OR2) presses
on the diffuser (2/E) the setting will not be correct
at first).
Generously grease O-ring (OR1) with silicon
grease and stage casing (60). Do not twist O-ring.
Place stage casing (60) on level and force down
sharply. Hit with a plastic hammer until it impacts.
Assemble pump down to the inside bearing casing
(54).
Slide on bearing sleeve (23), lubricate bearing
surface.
Mount inside bearing casing (54) with bearing
bushing (21) as for stage casing.
Mount first stage of the pump, secure impeller (1)
with washer (29) and nuts (28).
Tighten first nut (28) securely, then turn back by ¼
turn and secure with counter nut.
Mount suction casing (3) with O-ring (OR1), pull
pump with casing armature (25) and nuts (M1)
together slightly.
Align bearing surface of pump feet (place pump
on a flat surface).
Tighten nuts (M1), see table in Appendix for
torque.
Rotate shaft (24) to see that it runs smoothly.
Model MP:
Put off the impeller (1) with washer (29).
Tighten first nut (28) securely, then turn back by ¼
turn and secure with counter nut.
Model MPAI (Sizes 40.1 and 40.2)
Screw on the inducer (101), thereby fix the shaft
on the coupling against twist.
Model MPAI (Sizes 65.1, 65.2, 100.1, 100.2, 125.1
and 125.2)
Insert the key (PF5) and put the inducer (101) off.
Insert the washer (29).
Tighten first nut (28) securely, then turn back by ¼
turn and secure with counter nut.
Mount suction casing (3) with O-ring (OR1), pull
pump with casing armature (25) and nuts (M1)
together slightly.
Align bearing surface of pump feet (place pump
on a flat surface).
Tighten nuts (M1), see table in Appendix for
torque.
Rotate shaft (24) to see that it runs smoothly.
page 100
Model MP, MPA, MPAI
Issue 01/2007
Revision 02